niin

Aerial thermography · Utility-scale solar

Find the power your site is losing.

Aerial thermographic inspection of utility-scale solar farms, delivered as a module-by-module report.

Block 04 · Tracker 018 ΔT vs string
0.0+6.0 °C
Class 2 · schedule repair
Module
04-018-R2 · S-2 · #24
Fault
Bypass diode
ΔT over own module
+4.9 °C
Irradiance at capture
842 W/m²

Example readout

niin Software

Built by people who walk the rows.

With hands-on experience on solar sites, we built the software around the way a site is actually walked. The platform is our own, not a licence we resell, so if your site is documented differently or the report needs something extra, we can adapt it without waiting on anyone else.

  • 01No third-party platform sitting between your site and your report
  • 02The report follows your naming and your layout, not a fixed template
  • 03Changes are made by the people who wrote it, on our own timeline

What you get

What the report contains.

Every finding is tied to a single module: what the fault is, how much hotter it runs than the rest of its string, and where that module sits on the site.

01 / REPORT

Module-level addressing

Each finding carries its block, tracker, row, string and module position, counted the same way your crew counts in the field. Delivered as CSV and PDF.

02 / CLASSIFICATION

Fault type, not just heat

Cell hotspot, bypass diode, open string, whole-module and tracker-level events are separated by the shape of the thermal signature. A misaligned tracker is reported as one event, not as 50 module defects.

03 / EVIDENCE

Conditions on the record

Irradiance, wind, sky and gimbal angle logged per capture and checked against IEC 62446-3. Radiometric frames retained, so any finding can be re-opened later.

Process

We start by listening.

No two sites are run the same way. We ask how yours works first, and shape the report around it — your naming, your priorities, the format your team already uses.

STEP 1

Your brief

A call to understand what you need to find, how your team names and records assets, and what the report has to contain to be useful to you.

STEP 2

Your site on paper

Send whatever you already have — plans, spreadsheets, however your team names its blocks and rows. We work with your documents as they are, and tell you up front if anything is missing.

STEP 3

Survey and analysis

We fly the whole site during the hours when the sun is strong enough for the readings to count, then compare each panel against the ones it works alongside — so dirt or a passing cloud never ends up counted as a fault.

STEP 4

Your report

Every finding checked against its visible image, then delivered in the format we agreed — within a week of the last flight.

Survey specification

The numbers behind the report.

Aircraft & sensorDJI Matrice 4T · 640 × 512 radiometric thermal + visible
Survey altitude50 m AGL
Ground sampling distance≈ 6.6 cm/px — resolves single-cell hotspots
Temperature dataRaw radiometric, 1/64 K resolution — not screen colours
Irradiance window≥ 600 W/m², per IEC 62446-3
Typical throughput≈ 380,000 modules in about four field days
Reporting turnaroundWithin one week of the last flight
CoverageAustralia-wide

Scope

What every survey includes.

  • Full-site radiometric survey with the flight conditions logged per capture
  • Module-level report with physical addressing — block, tracker, string, module
  • Fault classification by thermal signature, with severity graded by ΔT
  • Tracker and string-level events grouped as single events, not repeated per module
  • Report delivered as CSV and PDF, with the radiometric frames retained

Get in touch

Ask for a quotation.

Send us the site details and we come back with a survey plan and a price. If you do not have the block count or module numbers to hand, leave them blank — we can work them out from your drawings.

Email
nixinsolar@gmail.com
Phone
+61 484 186 892
Coverage
Australia-wide
ABN
82 578 038 382
Opens in your email client.